Leading wire forming machine manufacturer specializing in the development of welding technology.
In resistance welding, an existing conductive connection can provide an alternative current path around the intended joint. This is commonly described as shunting. Its influence depends on the mesh geometry, material, contact network and welding arrangement. A weak weld alone does not prove shunting.
First check electrode condition, force delivery, joint contact, material identity and the approved welding schedule. Poor fit-up or inconsistent electrode contact can produce weak joints without an alternative path being the main cause. Keep the investigation tied to observable differences between samples.
Draw the panel with numbered weld positions and the actual welding order. Identify which neighboring joints already exist when each suspect weld is made. Include wire spacing, wire diameters, clamping contacts and any conductive fixture contact relevant to the circuit.
Compare the first joint with later joints made under nominally the same settings. A repeatable change associated with nearby completed welds is useful evidence, but it is not conclusive by itself. Electrode heating, surface changes and movement of the mesh can also occur as the sequence advances.
For the related upstream checks, see electrode wear and mesh weld quality. Use that guide alongside the checks described here.
Inspect electrode tips and seating under the approved isolation procedure. Confirm that the electrodes reach the intended crossing without side loading or interference. Record surface condition and fit-up. Cleaning or dressing must follow the electrode and machine instructions.
Do not compensate for uncertain contact simply by increasing current. That can increase expulsion, indentation or deformation while leaving the root cause unresolved. Establish a stable contact condition, then investigate how the existing mesh connections affect results.
Prepare comparable specimens from the same material lot. Hold electrode geometry, force, timing and inspection method constant. Compare an isolated or early joint with a joint made in the relevant completed-mesh condition. Document the exact difference between the trials.
Any electrical measurements should use suitable equipment and qualified personnel. A measured total secondary current is not automatically the current flowing through the target interface. Interpret waveforms with the welding system supplier rather than treating a controller display as direct proof of local joint heating.
Agree on the mechanical test method, sample location and acceptance criteria before the trial. Use the customer requirement for the joint and record the failure location or mode as well as the numerical result where applicable. A smooth-looking weld is not evidence of adequate strength.
Potential changes include sequence, spacing where the design permits, contact control or an approved schedule adjustment. Evaluate their effect on both joint performance and panel distortion. Keep the accepted sequence, fixture condition and schedule together in the setup record. Send Jinchun a panel drawing, material details, weld map and test requirement when discussing equipment.
For an equipment discussion, review the CNC wire mesh welding machine and ask Jinchun to assess the required part and acceptance method before confirming configuration.