Leading wire forming machine manufacturer specializing in the development of welding technology.
A fan guard can appear round and still fail assembly because its holes do not align with the mating component. The inspection must answer whether the released, cooled guard fits the specified interface without being forced into position. Overall diameter alone cannot establish the location of a mounting-hole pattern. Identify the mounting face, center reference and orientation on the current drawing before measuring.
Do not assume that the visible wire pattern defines the functional center. A formed seat, central bore or other locating feature may control assembly. Record which features establish the datum and which features are inspected from it. This prevents different operators from measuring different versions of the same apparent offset.
Clean the locating surfaces and inspect stops, pins and supports for wear or movement. Support the guard at the intended mounting surfaces without forcing it flat. A fixture that pushes a flexible part into shape can hide an assembly problem until the clamps are released.
Use a suitable coordinate method or validated functional gauge. Hole spacing alone does not establish the position of the entire pattern relative to the mounting center. Record individual locations where required, pattern orientation and functional center offset. Gauge clearances and acceptance limits must follow the drawing and inspection agreement, not an arbitrary shop-floor value.
Inspect the mounting ring before loading, after location or tack welding, after full welding and after release and cooling. Keep the datum scheme consistent wherever practical. If measuring a stage would disturb the setup, record that limitation rather than comparing incompatible conditions.
An incoming ring that is already outside its drawing needs a different correction from a ring that moves only during welding. If the part passes while clamped but fails after release, investigate restraint and residual movement. A common directional shift across several holes may indicate locating error rather than separate hole defects.
Try an approved mating component or assembly gauge in a defined condition. Check seating and fastener entry before tightening. Pulling the guard into place with screws is not dimensional acceptance. Record rocking, interference and orientation dependence. Where interchangeability matters, one unusually loose mating part is not sufficient evidence.
Keep sample ID, drawing revision, material lot, fixture version and cooled measurements together. Provide Jinchun Machine with the mounting drawing, wire specification and before-and-after records. Ask for a trial that includes final fit after release and cooling, not only an in-fixture demonstration.
Use this background to investigate movement introduced by welding. See wire mesh welding deformation guide.
Review the corresponding production-line application and discuss the mounting fixture and process scope. See fan guard production line.